BTL Polska Sp. z o.o.
BTL Polska Sp. z o.o.
Adres: Leonidasa 49, 02-239 Warszawa
Telefon: 22 667 02 76
WWW: https://www.btlnet.pl/

Podgląd wizytówki
INTIMEX
INTIMEX sp. z o.o. sp. k.
Adres: Egejska 19/39, 02-764 Warszawa
Telefon: +48 22 6687465
WWW: https://intimex.com.pl/

Podgląd wizytówki
Mindray
Mindray Medical Poland
Adres: Cybernetyki 9, 02-677 Warszawa
Telefon: 22 463 80 80
WWW: www.mindray.com

Podgląd wizytówki
Dräger Polska
Dräger Polska Sp. z o.o.
Adres: Posag 7 Panien 1, 02-495 Warszawa
Telefon: 22 243 06 58
WWW: https://www.draeger.com/pl_pl/Home

Podgląd wizytówki
United Imaging Healthcare
United Imaging Healthcare Poland
Adres: Żwirki i Wigury 14, 02-092 Warszawa
Telefon: +48 532 792 666
WWW: https://www.united-imaging.eu/pl/home

Podgląd wizytówki
SONOSCAPE MEDICAL CORP.
SONOSCAPE MEDICAL CORP.
Adres: Guangming District, Guangdong, 518107 Shenzhen
Telefon: +48 784 894 276
WWW: www.sonoscape.com

Podgląd wizytówki
ENDOELEKTRONIK.PL SP. Z O.O. SP.K.
ENDOELEKTRONIK.PL SP. Z O.O. SP.K.
Adres: ul. Borkowa 12, 05-840 Brwinów
Telefon: 22 758 51 48
WWW: https://endoelektronik.pl/

Podgląd wizytówki

Labsystems Life Science Multiskan FC


Labsystems Life Science Multiskan FC

Multiskan ™ FC jest kompaktowym, niezawodnym i solidnym fotometrem mikropłytkowym, zdolnym do odczytu 96-studzienkowych płytek do różnych zastosowań. Zapewnia szybki i dokładny pomiar z doskonałą liniowością. Jeden model z tej serii jest wyposażony w inkubator zapewniający kontrolę temperatury do 50 ° C i zdolność do odczytu płytek 384-dołkowych. Pomiar 96-studzienkowej płytki zajmuje tylko 6 sekund, a pomiar 384-studzienkowej płytki - 12 sekund. Zakres długości fal od 340 do 850 nm sprawia, że ​​Multiskan ™ FC nadaje się do zastosowań od kinetyki enzymów po testy Lowry'ego.

Główne cechy:

  • Łatwy w użyciu wielojęzyczny interfejs z dużym kolorowym ekranem
  • Używaj go jako samodzielnego urządzenia za pomocą wewnętrznego oprogramowania lub pod kontrolą komputera za pomocą oprogramowania SkanIt ™
  • Mały ślad oszczędza miejsce w laboratorium i ułatwia zautomatyzowane procedury
  • Port USB do łatwego przesyłania danych
  • Niezawodna wydajność z dnia na dzień i rok do roku
  • Kompatybilność z robotami w środowiskach o dużej przepustowości

Multiskan ™ FC (model IVD) z wewnętrznym oprogramowaniem jest zgodny z europejską dyrektywą IVD, co czyni go idealnym do jakościowych i ilościowych zastosowań ELISA w laboratoriach klinicznych.

Informacja o dostawie: Dostarczana w komplecie z trzema standardowymi filtrami (405, 450 i 620 nm) i oprogramowaniem SkanIt ™.

Specyfikacja:

Typ Multiskan™ FC Multiskan™ FC with incubator
Źródło światła Quartz-halogen lamp 6 V/10 W Quartz-halogen lamp 6 V/10 W
Zakres długości fali (nm) 340 - 850 340 - 850
Filter type 8-position filter wheel 8-position filter wheel
Filtry 340, 375, 405*, 414, 450*, 492, 520, 530, 540, 550, 560, 570, 595, 620*, 630, 650, 690, 740, 750, 820 nm filters (*standard filters)
340, 375, 405*, 414, 450*, 492, 520, 530, 540, 550, 560, 570, 595, 620*, 630, 650, 690, 740, 750, 820 nm filters (*standard filters)
Half bandwidth of filters 3 - 9 nm 3 - 9 nm
Plate types 96-well 96- and 384-well
Absorbance range 0 – 6 Abs 0 – 6 Abs
Rozdzielczość 0,001 Abs 0,001 Abs
Absorbance accuracy ±1% (0,3 - 3 Abs) at 405 nm
±2% (3 - 4 Abs) at 405 nm
±1% (0,3 - 3 Abs) at 405 nm
±2% (3 - 4 Abs) at 405 nm
Precyzja CV =0,2% (0,3 - 3 Abs) at 405 nm; CV =1,0% (3 - 4 Abs) at 405 nm in normal mode
CV =0,2% (0,3 - 3 Abs) at 405 nm; CV =1,0% (3 - 4 Abs) at 405 nm in normal mode
Linearity (96-well plate) 0 – 3 Abs, ± 2% (405 nm) 0 – 3 Abs, ± 2% (405 nm)
Linearity (384-well plate) - 0 – 2,5 Abs, ±2% (405 nm)
Measurement time (96-well plate) <6 s <6 s
Measurement time (384-well plate) - <12 s
Wyświetlacz High contrast colour display (480×272 dots)
High contrast colour display (480×272 dots)
Oprogramowanie Internal software or PC control with SkanIt™ software
Internal software or PC control with SkanIt™ software
Shaking Linear shaking, 3 speeds Linear shaking, 3 speeds
Optional incubator - Included
Zakres temperatury (°C) - Ambient +4...50
Interfejs USB for computer connection
USB memory stick for data export
USB for external printer ( HP PCL5 type)
USB for computer connection
USB memory stick for data export
USB for external printer ( HP PCL5 type)
Wymiary - szer. x gł. x wys. (mm) 290×400×210 290×400×210

Dostępne modele:

Opis Numer katalogowy VWR
Multiskan™ FC with integral shaker 736-0355P
Multiskan™ FC with integral shaker and incubator 736-0356P

Filtry:

Opis Numer katalogowy VWR
Optical filters, 340 nm 735-0400
Optical filters, 375 nm 736-0685
Optical filters, 405 nm 735-0401
Optical filters, 414 nm 735-0403
Optical filters, 450 nm 735-0406
Optical filters, 492 nm 735-0408
Optical filters, 520 nm 736-0686
Optical filters, 530 nm 736-0687
Optical filters, 540 nm 735-0411
Optical filters, 550 nm 735-0413
Optical filters, 560 nm 736-0688
Optical filters, 570 nm 735-0416
Optical filters, 595 nm 735-0420
Optical filters, 620 nm 735-0424
Optical filters, 630 nm 735-0426
Optical filters, 650 nm 735-0428
Optical filters, 690 nm 735-0430
Optical filters, 740 nm 736-0689
Optical filters, 750 nm 735-0432
Optical filters, 820 nm LABL1428205
Szerokość (mm): 290;
Wysokość (mm): 210;
Głębokość (mm): 400;
Brak akcesoriów
Brak materiałów dodatkowych

Nie wybrano pliku
Maksymalny rozmiar załącznika to 10MB.
Pole zgody na przetwarzanie danych osobowych jest wymagane.
WITKO Sp. z o.o.
92-332 Łódź, ul. Piłsudskiego 143
Telefon: 42 676 34 35
E-mail: Wyślij wiadomość
Przedstawiciel:
b/d
1 produkt w ofercie
Oferta Wyślij zapytanie