BTL Polska Sp. z o.o.
BTL Polska Sp. z o.o.
Adres: Leonidasa 49, 02-239 Warszawa
Telefon: 22 667 02 76
WWW: https://www.btlnet.pl/

Podgląd wizytówki
INTIMEX
INTIMEX sp. z o.o. sp. k.
Adres: Egejska 19/39, 02-764 Warszawa
Telefon: +48 22 6687465
WWW: https://intimex.com.pl/

Podgląd wizytówki
Mindray
Mindray Medical Poland
Adres: Cybernetyki 9, 02-677 Warszawa
Telefon: 22 463 80 80
WWW: www.mindray.com

Podgląd wizytówki
Dräger Polska
Dräger Polska Sp. z o.o.
Adres: Posag 7 Panien 1, 02-495 Warszawa
Telefon: 22 243 06 58
WWW: https://www.draeger.com/pl_pl/Home

Podgląd wizytówki
United Imaging Healthcare
United Imaging Healthcare Poland
Adres: Żwirki i Wigury 14, 02-092 Warszawa
Telefon: +48 532 792 666
WWW: https://www.united-imaging.eu/pl/home

Podgląd wizytówki
SONOSCAPE MEDICAL CORP.
SONOSCAPE MEDICAL CORP.
Adres: Guangming District, Guangdong, 518107 Shenzhen
Telefon: +48 784 894 276
WWW: www.sonoscape.com

Podgląd wizytówki
ENDOELEKTRONIK.PL SP. Z O.O. SP.K.
ENDOELEKTRONIK.PL SP. Z O.O. SP.K.
Adres: ul. Borkowa 12, 05-840 Brwinów
Telefon: 22 758 51 48
WWW: https://endoelektronik.pl/

Podgląd wizytówki

VWR Mastercycler X50


VWR Mastercycler X50

Mastercycler X50 to elegancka synteza szybkości, elastyczności i optymalizacji PCR do badań aplikacji PCR oraz standaryzacji do rutynowych aplikacji PCR, takich jak testy żywności. Mastercycler® X50 może pochwalić się szybkościami do 10 ° C / s i jest idealny do rutynowych zastosowań, a także do zaawansowanych badań w dziedzinie biologii molekularnej.

Główne cechy:

  • Szeroki wybór bloków od szybkiego bloku srebrnego do bloku 384-dołkowego
  • Innowacyjny gradient 2D do zaawansowanej optymalizacji PCR
  • X50 z ekranem dotykowym może kontrolować do 9 innych urządzeń
  • Koncepcja flexlid® umożliwia automatyczną regulację wysokości pokrywy w celu użycia wszystkich rodzajów materiałów eksploatacyjnych
  • Mały ślad

Rodzina Mastercycler X50 składa się z urządzeń z przyjaznym dla użytkownika interfejsem dotykowym lub urządzeń ekologicznych sterowanych zewnętrznie. Niski poziom hałasu, niskie zużycie energii i wszechstronna koncepcja flexlid® sprawiają, że produkt jest wydajnym i wygodnym cyklerem do PCR.

Gradient 2D umożliwia optymalizację zarówno temperatury denaturacji, jak i temperatury wyżarzania podczas tego samego przebiegu. Wyższe temperatury denaturacji mogą mieć tę zaletę, że zwiększają swoistość, podczas gdy niższe temperatury denaturacji zmniejszają obciążenie biomolekuł i mogą prowadzić do zwiększenia wydajności. Testy, które mają trudności z niezawodną pracą w temperaturze denaturacji 95 °, mogłyby znacznie skorzystać z optymalizacji temperatury denaturacji.

Zastosowania obejmują szybką PCR, optymalizację PCR, standardową PCR, inkubację i sekwencjonowanie cyklu.

Specyfikacja:

Typ Mastercycler X50s Mastercycler X50i Mastercycler X50a Mastercycler X50l Mastercycler X50p Mastercycler X50r Mastercycler X50h Mastercycler X50t
Zakres termostatowania (bloku) (°C) ≤±0,2 (at 20...72 °C)
≤±0,3 (at 72...95 °C)
≤±0,2 (at 20...72 °C)
≤±0,3 (at 72...95 °C)
≤±0,2 (at 20...72 °C)
≤±0,3 (at 72...95 °C)
≤±0,2 (at 20...72 °C)
≤±0,3 (at 72...95 °C)
≤±0,2 (at 20...72 °C)
≤±0,3 (at 72...95 °C)
≤±0,2 (at 20...72 °C)
≤±0,3 (at 72...95 °C)
≤±0,2 (at 20...72 °C)
≤±0,3 (at 72...95 °C)
≤±0,2 (at 20...72 °C)
≤±0,3 (at 72...95 °C)
Temperatura pokrywy (°C) 37...110 37...110 37...110 37...110 37...110 37...110 37...110 37...110
Zakres termostatowania gradientu (°C) 30...99 30...99 30...99 30...99 30...99 30...99 30...99 30...99
Operating conditions (°C, % RH) 15...35 °C/75% RH 15...35 °C/75% RH 15...35 °C/75% RH 15...35 °C/75% RH 15...35 °C/75% RH 15...35 °C/75% RH 15...35 °C/75% RH 15...35 °C/75% RH
Moc (W) 850 850 850 850 850 850 850 850
Ilość próbek 96×0,1 ml PCR tubes
96×0,2 ml PCR tubes
one 96-well PCR plate (unskirted, semi-skirted, skirted and low profile)
96×0,1 ml PCR tubes
96×0,2 ml PCR tubes
one 96-well PCR plate (unskirted, semi-skirted, skirted and low profile)
96×0,1 ml PCR tubes
96×0,2 ml PCR tubes
one 96-well PCR plate (unskirted, semi-skirted, skirted and low profile)
96×0,1 ml PCR tubes
96×0,2 ml PCR tubes
one 96-well PCR plate (unskirted, semi-skirted, skirted and low profile)
one 96-well PCR plate (unskirted, semi-skirted, skirted and low profile) one 96-well PCR plate (unskirted, semi-skirted, skirted and low profile) one 384-well PCR plate one 384-well PCR plate
Wymiary - szer. x gł. x wys. (mm) 275×430×330 275×430×330 275×430×330 275×430×330 275×430×330 275×430×330 275×430×330 275×430×330
Waga (kg) 11,5 10,5 11,5 10,5 11,5 10,5 11,5 10,5
Block temperature range 4...99 °C 4...99 °C 4...99 °C 4...99 °C 4...99 °C 4...99 °C 4...99 °C 4...99 °C
Heating ramp rate max. 10 °C/s max. 10 °C/s max. 5 °C/s max. 5 °C/s max. 5 °C/s max. 5 °C/s max. 5 °C/s max. 5 °C/s
Cooling ramp rate max.5 °C max.5 °C max. 2,3 °C/s max. 2,3 °C/s max. 2,3 °C/s max. 2,3 °C/s max. 2,3 °C/s max. 2,3 °C/s
Control accuracy ±0,15 °C ±0,15 °C ±0,15 °C ±0,15 °C ±0,15 °C ±0,15 °C ±0,15 °C ±0,15 °C
Zasilanie 110 - 230 V, 50 - 60 Hz 110 - 230 V, 50 - 60 Hz 110 - 230 V, 50 - 60 Hz 110 - 230 V, 50 - 60 Hz 110 - 230 V, 50 - 60 Hz 110 - 230 V, 50 - 60 Hz 110 - 230 V, 50 - 60 Hz 110 - 230 V, 50 - 60 Hz
Zakres temperatur pokrywy (°C): 37 - 110;
Masa (kg): 10,5; 11,5;
Brak akcesoriów
Brak materiałów dodatkowych

Nie wybrano pliku
Maksymalny rozmiar załącznika to 10MB.
Pole zgody na przetwarzanie danych osobowych jest wymagane.
Chcesz poznać ofertę tego produktu? Skontaktujemy Cię z dystrybutorem. Napisz do nas medipment@amdg.net.pl, zadzwoń 663 263 423, lub wybierz czat online w prawym dolnym rogu.